PROJECT DESIGN
Complete all your Cable calculations, tables with fully marked up Single line drawings faster than you thought possible You can Design and build Your Installation starting from scratch.
 
Full Installation Design capability (Switch Board / Dist.Board is limited to 1,000)
Now you can produce all your results the quick and easy way showing:-
- Cable sizes,
- Voltage drops
- Conduit sizes and capacities
- Fault levels
- Fuse/CB sizes
- Installed cable temperatures
- Single line drawings (fully marked up with all your results)
- Tables with All Your calculation Results.
Here’s how the program works, simply…
1: Input The cable length of run, Load current and amount of voltage drop i.e. 2.5%
2: Select Cable material, Method of Installation and Circuit protection i.e. fuse/cb

The program will instantly create your single line drawings fully marked up with all your cable calculation results

From Mains cables, Sub mains and all your Final sub-circuits.

Single Line Drawings…No Problem!
Now you can produce all your “Single line” and “As built” drawings fully marked up with all your Calculation Results in Just minutes!

You can print out all your calculations, tables and drawings and print to PDF for easy emailing. Flexibility to save as a dxf file and open Cad based software

Thousands now Design and Draft their own Installation projects. Start now by using this program to produce Electrical Installation Designs quickly and easily.

Single Line drawings fully marked up, no drafting experience required!
Table with all your calculation results automatically produced and ready to print!
Start Using PROJECT DESIGN today and discover how the software (and you) can deliver a quality engineering result.
Spare Capacity can be engineered in to Your Design!
There are occasions when producing the Lowest cost design may not be your priority for instance:-

1: You may have to engineer in “spare capacity” to allow for extra loads to be fitted for future expansion, now it’s just a mouse click away.
2: You may have to fit a minimum specified cable size for your Mains, Sub-mains and final sub-circuits it’s easy to select your own cable size

Compliance Checking Existing Installations you can
1: Check an existing installation for full compliance
2: Add extra loads to an existing installation
3: Change or modify an existing installation
4: Find out remaining voltage drops at your boards.
5: Re-design it completely.

What ever the reason you can input an existing installation and check it for full compliance and if neccessary make any adjustments to comply with the regulations.

Get the edge over all your competitors by completing your design in-house.
Testimonials
REQUEST MORE INFORMATION:
Name:
Business:
Email:
Phone:
Country:

Privacy & Returns Policy